Alpine Supply Company 36 Direct Vent Gas Fireplace
INSTALLATION INSTRUCTIONS
Fig. 31– Door Assembly Installation
Pull hook forward
and up to slot
on door bracket
Fig. 32– Door Locking Assembly
REMOTE CONTROL (Optional)
An Alpine Remote Control Kit (08501) may be installed
on this fireplace. The remote control kit comes with a
hand held transmitter, a receiver, a wall mounting plate,
The remote control is thermostatically controlled so you
can set the fireplace to the desired room temperature, and
have that temperature maintained. The remote control is
battery powered and will require periodic maintenance to
keep the system working properly.
1. Choose a convenient location on the wall to install the
receiver unit. A 22 Cu.In electrical box may be used. Run
wires from the fireplace valve to the desired wall
location. See the millivolt lead table on page 14 of this
manual for maximum wire runs.
2. Connect the wires to the gas valve (see figure 32).
3. Follow the installation instructions included with the
remote control kit.
LO
HI



Fig.33– Gas Valve Connection
WALL THERMOSTAT (Optional)
A wall thermostat may be installed if desired. Follow the
wire routing instructions on page 12 of this manual.
Alpine offers two types of wall mounted thermostats.
One is a basic heating type thermostat (part # 08260).
The other is a model (part # 08261). See your Alpine
dealer for additional information on the thermostats.
NOTE: If a Wall Thermostat is desired, there is no
need to install a wall junction box. The thermostat
wire will simply need to be routed to the desired
location of the wall thermostat and made accessible
through a small hole in the drywall. Both types of
thermostats are surface mounted on the finished wall.
They should not be installed until painting is
complete.
PILOT
TP TH
TP TH
TO WALL SWITCH
REMOTE CONTROL
OR THERMOSTAT
Thermopile
6. Ignite the pilot assembly and test fire the burner. The
flame should flow smoothly to all points on the burner.
If the burner does not burn from all ports. Turn the appli-
ance off and contact your Alpine Dealer before using the
appliance.