16
Figure 35 Parametric Equaliser Frequency menu
The frequency of each band may be adjusted using the
rotary controller, the avilable frequencies depends on the
band and the relative values of the adjacent bands. The
range of each band is as follows:
Band 1 20Hz 80Hz
Band 2 50Hz 200Hz
Band 3 125Hz 3.2KHz
Band 4 315Hz 8KHz
Band 5 800Hz 20KHz
The frequency of a band must be at least one step clear of the band to either side. The following
frequencies are avilable:
20Hz, 25Hz, 31Hz, 40Hz, 50Hz, 63HZ, 80Hz, 100Hz, 125Hz,
160Hz, 200Hz, 250Hz, 315Hz, 400Hz, 500Hz, 630Hz, 800Hz, 1.0KHz,
1.2KHz, 1.6KHz, 2.0KHz, 2.5KHz, 3.2KHz, 4.0KHz, 5.0KHz, 6.3KHz, 8.0KHz,
10KHz, 12.5KHz, 16KHz, 20KHz
So, for example, if band 4 is set to 4.0KHz, band 3 can be set no higher than 2.5KHz and band 5 can be set
no lower than 6.3KHz.
Figure 36 Parametric Equaliser Level menu
The level of each band can be adjusted using the rotary
controller between -6dB and +6dB.